echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Drugs Articles > Production process of concentrated pills

    Production process of concentrated pills

    • Last Update: 2010-04-09
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    1、 Instructions for use of concentrated pill machine 1 Before use of the machine, remove the upper cover shell and gearbox cover, add several drops of water-free edible oil at each oil hole, and then scrub four rollers and parts contacting with the pill with medical alcohol for disinfection 2 Reinstall the upper cover shell and gearbox cover, connect the power supply, turn on the switch, and turn the machine for 1-2 minutes 3 Put the evenly distributed agglomerated charge into the extruder, draw out the strips, and then put the strips crosswise in the pill making groove to directly rub them into pills 4 Coating: after the pill is made, it can be put in the water pill coating device and wrapped into white, red and other coats 5 Drying method: after the pill is made, put the pill into the water pill coater for electric heating or drying, or dry it with the hot air of the electric dryer, or directly in the sun 6 Polishing method: put the pill in the water pill coater and roll continuously The longer rolling time is, the smoother the surface is 2 Instructions for users of concentrated pills 1 This machine is suitable for the environment temperature of - 5 ℃ to 40 ℃, and the relative humidity is less than 90% There is no conductive dust and corrosive metal gas around, and it is placed in a ventilated and clean position 2 During operation, there shall be no other irrelevant items on the worktable The pelletizer shall be placed on a stable platform When the power supply voltage is confirmed, the power supply shall be close to the platform, and the power socket shall have a reliable grounding wire It is strictly prohibited to pull the power cord forcibly to prevent man-made overturning, damaging the pelletizer and other accidents 3 After the machine is used, remove the socket head cap screw, divide the upper part and the lower part with the roller as the boundary, remove the four rollers, scrub them with medical alcohol, and then install and reset them 4 In order to avoid personal accident, the main power supply must be cut off and the power plug must be pulled out when cleaning and changing the pill roller with medical alcohol 5 During the operation of pelletizer, it is strictly prohibited to contact the pelletizing roller by hand, brush or other tools to avoid stabbing fingers It is strictly prohibited to process pelletizer with electricity under the protection of no upper cover and gearbox cover, so as to avoid unnecessary personal accidents 6 If the power cord is damaged (such as exposed bare wire, etc.), special power cord must be used Purchase and replace it in the maintenance department of the local office In case of failure of switch or socket, it is necessary to stop using It is strictly prohibited to change the line for further use The head or socket of the same specification shall be replaced in time to avoid mechanical and personal accidents 7 The matching comminuting equipment of this machine can be the lh-08b flow mill or xfb-400g to 500g swing mill 8 When the water pill coating device is not used, it can be removed and washed directly Turn clockwise and pull it out Put it in a reliable and clean place for use, and apply a small amount of clean and anhydrous edible oil on the exposed part of the water pill coater to prevent floating rust It is forbidden to wash the whole machine or electric heater directly with water When the machine is not in use, it must be placed in a dry, clean and ventilated place During the use of electric heater, it is strictly prohibited to contact with water to prevent electric conduction and personal accidents such as electric shock III name of concentrated pill machine accessories, specification, quantity of accessories, injection heating plate 80 × 105mm, 1kW 1 power line 0.75mm M2 × 1.8m 1 1.5mm × 1.8m 1 tray 27cm × 20cm 1 Daily necessities water sprayer 0.5kg 1 daily necessities IV causes of common faults of concentrated pills and Solutions Common faults of this machine cause that the power supply must be cut off in order to carry out the following operations 1 After this machine is powered on, The motor is not running 1 The power cord is in poor contact or the power plug is loose; 2 The switch is in poor contact 1 Repair the power supply or replace the plug of the same specification; 2 Repair or replace the switch of the same specification 2 When the machine-made pill is used, the shaft knife rotates or the medicine surface is stuck with a groove The discharging baffle plate is loose and has a distance from the bottom of the shaft knife Zui, so the pill cannot be scraped from the shaft knife groove Adjust the distance between the discharge plate and the Zui bottom of the shaft knife slot (about 0.1mm) and tighten the fixing screws 3 When the machine is working, the motor stops suddenly 1 Capacitor open circuit 2 Gear stuck Check the gear groove for sundries and clean it 4 When the machine is working, the shaft knife has a slight runout Open the upper cover and tighten the 6 socket head screws evenly 5 This machine produces abnormal noise during operation 1 The friction part between the shaft cutter and the machine body is dry and oil-free; 2 There is no oil between the gears 1 Pour several drops of clean edible oil into the oil hole; 2 Apply a small amount of butter to each gear groove 6 Heater heating failure 1 The plug is loose or the power line falls off; the plug of the same specification is replaced or the power socket is repaired; v the high-voltage stripper is made of the material refined by the company, beautiful, clean, reliable in quality, light in use and easy to carry 6、 Operation method of concentrated pill: 1 Loosen the adjusting screw 1 and move the movable leg 2 to use the size of the pot 2 Lower the rack 3 to the bottom of the Zui, make the indenter contact the panel, and lock the limit nut 4 to avoid the over position of the end of the pressure surface 3 Turn the handle 6 to raise the rack 3 to the Zui high position 4 Use the face cylinder 7 to the dotted line position, and install the pressed material 5 After the pressing material is loaded, it is moved back to its original position 6 Turn the handle 6 so that the rack 3 is lowered to the point where there is no gap between the pressed materials 7、 Hold the handle 6, do not reverse the gear, shake the pressure bar 5 up and down to press 8 Turn out part No 8 to clean the face cylinder and panel Hunan Zhongcheng pharmaceutical machinery factory has many varieties, which are suitable for all pharmacies, clinics, pharmaceutical factories and hospitals The quality is guaranteed If you are not satisfied with seven days' return, one year's quality and life-long maintenance, you are welcome to log in to our company: or directly: for consultation, our factory will provide you with more professional services!
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.