    Simple trouble of automatic air shower room and its troubleshooting skills

    • Last Update: 2020-01-03
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Automatic air shower The main function is to remove the dust on the human body by blowing and drenching, so as to achieve the purpose of purification Only with enough wind, most of the dust on the human body can be removed Of course, this is only one of the functions of the wind drenching room During the later use of the equipment, it is inevitable that there are faults, so it is very important to master the troubleshooting skills of common faults of the equipment The following is full-automatic Simple faults and troubleshooting skills of the air shower room, I hope to help you! 1 Power switch Generally, the air shower room has three places to cut off the power: 1 Power switch of the air shower outdoor box; 2 Control panel of the air shower indoor box; 3 On the external boxes on both sides of the air shower room (the power switch here can prevent the power supply from being cut off in case of emergency, effectively improving the personal safety of the staff) When the power indicator is not working, it is not necessary to recheck the power supply of the above three air shower rooms 2、 When the fan in the air shower room is not working, check whether the emergency switch of the box outside the air shower room is cut off If it is cut off, gently press it with your hand and turn it to the right to release it 3、 If the air shower can not automatically sense the spray, please check the light sensing system at the lower right corner of the air shower box to see whether the light sensing device is installed correctly If the two sides of the light sensing are facing each other and the light sensing is normal, it can automatically sense 4、 If the wind speed in the air shower room is very low for a period of time, please check whether there is too much dust on the primary and high-efficiency filters in the air shower room If so, please replace the filters (the primary filter in the air shower shall be replaced once in 1-6 months, and the high-efficiency filter in the air shower shall be replaced once in 6-12 months) 5、 If the fan in the air shower room is reversed or the wind speed in the air shower room is very small, please check whether the 380V three-phase four wire line is reversed The manufacturer of the general air shower room will have a specially assigned electrician to connect the line before delivery and installation; If the wire source of the air shower is reversed, the light one will cause the fan of the air shower not to work or the reverse one will reduce the wind speed of the air shower, and the heavy one will burn the circuit board of the whole air shower It is recommended that the enterprise using the air shower should not change the wiring lightly If it is determined to move due to production needs, please consult the manufacturer of the air shower for solutions 6、 In addition to the above three points, it is also necessary to check whether the emergency stop key inside the air shower box is pressed If the emergency stop key is red, the air shower will not blow; if the emergency stop key is pressed again, it can work normally
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.