    Stainless steel manufacturing hot and cold all-in-one machine has many characteristics, the use of fully automatic mode, automatic heating and cooling, can reduce energy consumption, improve product molding efficiency, is currently a relatively widely used equipment.
    should pay attention to the requirements when using, strictly abide by the operating procedures, otherwise it is easy to have problems.
    addition, maintenance is also very important.
    the following small editor for you to introduce the characteristics of the hot and cold all-in-one machine, the use of requirements and maintenance methods, let's take a look.
    are the characteristics of the hot and cold all-in-one? 1, fully automatic: design reserved positions, can be fully automatic.
    2, automatic control: pLc automatic control, automatic alarm of fault.
    3, the finished product rate is high: the whole photoelectrelectrelectr of tracking, the finished product rate is high.
    4, reserve manual mode: reserve manual mode can be any special case, artificial adjustment.
    requirements for the use of hot and cold all-in-one machines? 1, hot and cold all-in-one machine should be operated by a special person to manage, find abnormal timely shutdown and find out the cause, troubleshooting, strictly prohibited with fault operation unit adjustment has reached the working state.
    2, special attention is that users do not arbitrarily change the set operating parameters, changes may cause unnecessary impact on the product, the effect does not say, if other failures or affect the safety of life.
    3, the main circuit power switch of the product cannot be disconnected during normal service period to maintain the normal operation of the compressor oil heater.
    is strictly prohibited to operate each switch frequently, the number of power-on times should not exceed 6 times / hour, and the start-up time should be more than 5 minutes.
    the condenser and evaporator at least once every two years.
    this makes the product life longer, but also stable effect.
    the maintenance methods of the hot and cold all-in-one machine? 1, hot and cold all-in-one machine power wiring fastening bolts are loose.
    the high and low pressure values of the refrigeration/thermal system are correct.
    the operating current of the compressor of the hot and cold all-in-one compressor and whether the insulation resistance of the unit is normal.
    2, drying filter and mirror is normal, such as filter outlet frosting, indicating that the filter is dirty, need to clean the filter, if the mirror has humidity display (color red), you need to replace the drying filter core.
    3, ice-hot all-in-one compressor lubricants are normal, operating if the oil level is lower than 2/3 of the mirror, should add lubricants, if there is dirt or has become bad, should replace the lubricant, and clean or replace the oil filter, while replacing the drying filter core.
    4, the operating pressure of the general mode temperature controller is 2-5 bar (29-72.5psi), because the pressure is insufficient to affect the volume flow rate of the coolant (flow resistance results in pressure loss), so the higher the pressure of the pump, the more stable the flow rate.
    the design of the refrigeration line of the mold temperature controller and the components are important for the control of the mold temperature.
    when the temperature of the mold or thermostat rises to the set value, the die temperature controller needs to be able to quickly and effectively avoid further temperature increases.
    above is the small editor for you to introduce the characteristics of the hot and cold all-in-one machine and the use of requirements, I think you have a certain understanding after reading, if there is any doubt can contact us.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.