    What are the safety precautions for vacuum emulsifiers?

    • Last Update: 2020-07-29
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Vacuum emulsifier as a large-scale production equipment, in order to operator's personal safety, in the operation of the time have rules and safety precautions, the following small editor to give us a detailed explanation of which places need to pay attention to: 1, after production, it is necessary to vacuum emulsifier clean clean, so that both adhere to the determination, rotor use life and operating efficiency can also play a role in maintaining the seal of the emulsifierIf necessary, a set of cleaning cycle equipment can be planned at the periphery2, vacuum emulsifier operation if found that the shaft has liquid leakage phenomenon, it is necessary to adjust the pressure of the machine seal after the shutdown3, emulsifier admitted to the machine seal cooling water, start the motor, must ensure that the motor steering and the steering mark of the spindle consistent before operating, prohibit swing!4, according to the user's use of materials, the import and export filter is necessary to make regular cleaning to prevent the reduction of feed volume and affect the production efficiencyThe material into the working cavity is necessary to be fluid, do not allow dry powder, clumps of material directly into the machine, otherwise, it is very simple to form a smouldering machine and damage the vacuum emulsifier5, prohibit metal chips or solid hard-to-break debris into the vacuum emulsifier operating cavity, in order to the stator, rotor and other equipment to form a devastating damage6, in the use of vacuum emulsifier to develop the corresponding safe production procedures to ensure the safety of operators and equipmentIn the electrical control system users to set up a safety maintenance system, and have a good and reliable electrical motor grounding equipment7, vacuum emulsifier process operating cavity can be separated with insulation layer, for the cooling or heating of materials, power on the first switch on coolant or thermal oilInsulation mezzanine operating pressure of 0.2Mpa, in the processing of temperature requirements, it is necessary to heat or cool to the normal operating temperature, crate, power on8, emulsifier in flammable, explosive operating environment, it is necessary to choose the appropriate level of explosion-proof motorCan contact our customer service customization 9, generally only after a high self-weight to TRL1 pipeline equipment into the material, feed is necessary to enter successively, adhere to the material has better liquidityAnd when the material fluidity is poor, the viscosity of 4000CP when the SRH pipeline equipment import to be equipped with a conveying pump, pump ingest pressure 0.3MpaThe selected pump should be colloidal pump and the flow rate matches the flow scale of the selected pipeline emulsifier10, GENERALLY OPEN THE VACUUM EMULSIFIER BEFORE CONNECTING THE MECHANICAL SEAL OF COOLING WATER, SHUTDOWN FIRST SHUT DOWN AND THEN BLOCK THE COOLING WATERCooling water can be selected with tap waterIt is necessary for materials to enter the working cavity before powering on, and to ensure that the operation is not broken to prevent the empty turn so that the mechanical seal burned due to high temperature or affect the use of life Cooling water import and export connectors are equipped with hose-size inner diameters 11, vacuum emulsifier should be regularly checked fixed, rotor, found that wear is too large, should promptly replace the corresponding components to ensure dispersion, emulsification of the role 12, in the use of vacuum emulsifier, liquid materials need to be successively input or in the container to adhere to the certain amount Should prevent vacuum emulsifier empty machine operation, to prevent materials in the operation of high temperature or crystalline curing and damage equipment!13, vacuum emulsifier in the course of operation once abnormal noise or other fault, should immediately stop to view, to troubleshoot and then work After the shutdown should be the work cavity and fixed, rotor cleaning clean
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.