echemi logo
Product
  • Product
  • Supplier
  • Inquiry
    Home > Active Ingredient News > Drugs Articles > Working principle of clean sampling vehicle

    Working principle of clean sampling vehicle

    • Last Update: 2016-12-12
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    Clean sampling vehicle (also known as clean sampling vehicle) is a kind of vertical one-way flow local air purification equipment that can provide local clean environment It can flow flexibly in the workshop, making up for the cleanliness requirements of some spaces which cannot be achieved by fixed laminar flow hood, air purifier and other equipment The clean sampling vehicle is an ideal mobile equipment for sampling and goods delivery in the pharmaceutical and health, biological products, food, electronic industries, etc., and also an essential equipment specified in Article 22 of GMP According to the GMP standard, the sampling car produced by klcfilter has a cleanliness level of 10000 (Zui up to 100), and the electric components used at the same time comply with the provisions of gb1497-85 (electric safety standard) and gb-191 (packaging standard) The structure of the clean sampling car is composed of stainless steel or spray plastic steel plate box The body is composed of prefilter, air supply unit, filter, lighting group, diffuser, combined electrical appliance, caster and other combinations The whole equipment is compact in structure and easy to operate Working principle of clean sampling vehicle: the working principle of clean sampling vehicle adopts the air flow form of vertical laminar flow The variable speed centrifugal fan presses the air filtered by the prefilter in the negative pressure box into the static pressure box, and then the air is filtered by the filter for the second time When the clean air flow from the air outlet of rfilter filter passes through the work area with a certain uniform cross-section wind speed, the dust particles and biological particles will be taken away, thus forming a dust-free and sterile work environment The structure features of the clean sampling car: 1 The upper half of the clean sampling car is the air supply static pressure box, the lower half is the clean area, and the box body is stainless steel The air supply body is equipped with a filter made of ultra-fine glass fiber filter material, a multi wing forward-looking low-noise variable-speed centrifugal fan, and a lighting fluorescent lamp and an ultraviolet sterilization lamp are installed on the diffuser of the air outlet surface In order to facilitate the work and observation of the staff, the baffles on both sides of the operation surface of the clean work area are made of transparent glass, and the front and rear windscreens are made of transparent environmental protection material plastic 2 Variable speed fan system with adjustable air volume is adopted for the clean sampling vehicle By adjusting the input voltage of variable speed fan and changing the working condition of the fan, the average wind speed in the purification working area is kept in the ideal range all the time, which can effectively extend the service life of the main components (air filter) of the clean sampling vehicle and reduce the operating cost of the clean sampling vehicle 3 The ultraviolet sterilization lamp used in the clean sampling vehicle can radiate a strong 2573a short wave ultraviolet It can kill not only the active cells of microorganisms, but also the spores (such as Bacillus subtilis) and other bacterial spores with strong heat resistance In addition, phage and virus can also be destroyed rapidly under the action of UV Installation and use conditions of clean sampling vehicle 1 The storage place of clean sampling vehicle shall be far away from the source, ventilated and dry, And the number of dust particles with particle size ≥ 0.5 μ m in the air per liter is ≤ 3500 (equivalent to 100000 class in 209b of American federal standard) 2 The wind speed of the clean sampling vehicle has been adjusted to the ideal state (i.e the average wind speed of the clean working area is 0.32m/s-0.48m / s at this time) 3 after the installation of the clean sampling vehicle, The average wind speed in the purification work area can be measured with a tachometer The operating procedures and precautions of the clean sampling car with the wind speed controlled between 0.32m/s and 0.48m/s (regulated voltage) shall be as follows: 1 when using the clean sampling car, turn on the ultraviolet sterilization lamp 50 minutes in advance to deal with the microorganism accumulated on the surface of the clean sampling car in the purification work area; turn off the sterilization lamp 30 minutes later, Start the forced draft fan 2 for the newly installed or long-term unused clean sampling vehicle, clean the vehicle and the surrounding environment before work, first use the ultra clean vacuum cleaner or the tool that does not produce fiber, carefully clean the vehicle, and then use the drug sterilization method or ultraviolet sterilization method for sterilization 3 it is strictly prohibited to store unnecessary articles in the purification work area, In order to keep the clean air flow pattern free from interference 4 Try to avoid disturbing the air flow pattern obviously in the purification work area 5 Measure the average wind speed of the work area with an anemometer regularly (usually once a month) If it is found that it does not meet the technical indicators, adjust the handle of the voltage regulator to change the input voltage of the fan, Make the clean sampling vehicle in an ideal working condition 6 the service temperature of the clean sampling vehicle shall not be greater than 50 ℃ 1 according to the cleanliness of the environment, remove and clean the filter material in the coarse filter regularly The interval is generally 2-3 months In general, when the non-woven filter material contains more dust particles and the surface turns black, it can be removed for cleaning or replaced 2 Sterilize the environment regularly (usually for one week) 3 Measure the cleanliness of the working area with a dust particle counter every three months, and measure the average colony number of the clean sampling vehicle with a plate method When the technical parameters are not met, the reason must be found, Timely maintenance 4 when the input voltage of the blower has failed to make the average wind speed of the purification work area reach 0.32m/s-0.48m/s, it means that the dust capacity of the air filter tends to be saturated and has failed, and it must be replaced 5 when replacing the filter, the cover plate on the top of the clean sampling car must be opened before installation When installing the air filter, the arrow mark shall be pointed to the air flow direction, (down) 6 after replacing the filter, check with the dust particle counter to check whether the seal around the rim is good It is necessary to use silica gel for plugging Then adjust the input voltage of the fan to keep the average wind speed in the purification area within the range of 0.32m/s to 0.48m/s 7 Otherwise, it will affect the sterilization ability 8 for electrical faults, please refer to the electrical schematic diagram and electrical wiring diagram for maintenance 9 for maintenance and inspection once a month, and fill in the instrument maintenance record 10 after each use, clean the instrument immediately, hang the corresponding marks, and fill in the instrument use record in time 1 for cleaning the sampling vehicle After the reclaiming, brush away the sundries and floating dust in the clean working area with a brush 2 Wipe the dirt and dirt on the inner surface of the working area with a fine soft cloth There is no detergent residue by visual inspection Wipe it dry with a clean cloth 3 Wipe the surface of UV sterilization lamp with gauze and alcohol frequently to keep the surface clean, otherwise it will affect the sterilization ability 4 Effect evaluation: the internal and external surfaces of the equipment shall be bright and clean without stains Shanghai Sujing Industry Co., Ltd if you have any need, you can pass with us at any time Thank you very much for your support and look forward to cooperating with you Thank you & bestragard! Suing Jinghua
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Related Articles

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.