    Common faults and solutions of automatic labeling machine

    • Last Update: 2018-11-08
    • Source: Internet
    • Author: User
    Search more information of high quality chemicals, good prices and reliable suppliers, visit www.echemi.com
    In the process of using the automatic labeling machine, there will always be more or less many problems, and there are three common failures Let's share with you how to solve these problems quickly and effectively 1 Wrinkle treatment after labeling: (1) the speed of bid delivery is faster than the linear speed of the material running surface, and the speed of bid delivery can be reduced (2) the bid delivery is too early, move the electronic eye of the object to the right, (3) the label is too long, and the length of the pre bid delivery can be reduced (4) the speed of the label is not fast enough, and the speed of the label can be increased 2 The labeling machine can't stick the label: (1) the labeling speed is too slow, so you can adjust the labeling speed higher (2) the position of the electronic eye of the object is wrong, and you can adjust the position of the electronic eye of the object (3) the label is not long enough, and you can adjust the length of the reserved label (4) the electronic eye of the object is too far away from the labeling end, just move the electronic eye of the object to the right (5) if no material is detected by the electronic eye for measuring objects, adjust the electronic eye for measuring objects (6) the distance between materials is too small, and increase the distance between materials 3 The labeling machine does not provide label treatment methods: (1) the position of the electronic eye for measuring objects is not correct, adjust the position of the electronic eye for measuring objects (2) if the electronic eye for measuring objects fails, replace the electronic eye for measuring objects (3) there is not enough pulling paper for pasting head label Adjust the pulling paper tightly (4) the color of the pasted object cannot be sensed by the electric eye Replace the electric eye with proper model and function (5) the marker feeder is not opened, and the marker feeder can be opened 4 The reasons that cannot be sensed are usually as follows for reference: (1) the sensitivity of the sensor switch needs to be adjusted Solution: need to adjust the sensitivity (2) the inductive switch is not suitable for the measured object Solution: replace the inductive switch (3) causes caused by the control system, such as program control According to the relevant circuit Of course, if other objects can be tested, this item can be excluded.
    This article is an English version of an article which is originally in the Chinese language on echemi.com and is provided for information purposes only. This website makes no representation or warranty of any kind, either expressed or implied, as to the accuracy, completeness ownership or reliability of the article or any translations thereof. If you have any concerns or complaints relating to the article, please send an email, providing a detailed description of the concern or complaint, to service@echemi.com. A staff member will contact you within 5 working days. Once verified, infringing content will be removed immediately.

    Related Articles

    Contact Us

    The source of this page with content of products and services is from Internet, which doesn't represent ECHEMI's opinion. If you have any queries, please write to service@echemi.com. It will be replied within 5 days.

    Moreover, if you find any instances of plagiarism from the page, please send email to service@echemi.com with relevant evidence.